GE 7000 HSX

Generator petrol HONDA GX 390 - Single-phase synchronous alternator - Single-phase power  5.5 kVA (5 kW) – Electric Starter

MOSA model GE 7000 HSX  is a compact petrol generating set, the model feature 20 litre fuel tanks for 8 hours continuous operation and are easily transportable using the optional moving wheels thanks to its weight 155kg.

The design incorporates a steel structure with engine and alternator mounted on anti-vibration dampers to increase service life and reduce noise. A recessed panel protects the sockets and controls from accidental damage whilst a tubular steel frame provides protection for the complete machine

EAS
models are pre-wired to accept the optional MOSA EAS Automatic Start-Up Panel which plugs into the front panel of the Generator and enables the machine to be used as an emergency standby power unit in the event of power failure from the mains supply.

The control panel
houses the sockets and machine controls including ELCB-GFI, circuit breaker and Thermal shut off.

Also available is an optional TCM remote control allowing start/stop of the engine up to 10 metres distance from the machine

Suitable for a wide range of uses in general construction, equipment rental, events and standby applications.

In according with CE regulation

More Information

Engine

Model Fuel Starter Output Stand By Output PRP Cylinders / Displacement Speed Cooled
HONDA GX 390 Petrol Eletric 8.2 kW (11.1 HP) 6.4 kW (8.7 HP) 1/ 389 cm3 3000 rpm Air

Technical Features

Single-Phase synchronous alternator, self-excited, self-regulated, brushless
  • Stand-by single-phase power: 6,7 kVA (6 kW) / 230 V / 29,1 A
  • PRP single-phase power: 5,5 kVA (5 kW) / 230 V / 23,9 A
  • Dimensions: 1060x570x665 mm
  • Dry weight: 155 kg
  • Measured Acoustic power LwA (pressure LpA): 88 dB(A) (63 dB(A) @ 7m)
  • Guaranteed Acoustic power LwA (pressure LpA): 89 dB(A) (64 dB(A) @ 7m)

VERSIONS ON REQUEST
  • SCHUKO sockets

Oil Alert

sample powersafe The “Oil Alert” system is designed to prevent damage to the engine due to an insufficient quantity of oil in the engine sump.

This system automatically shuts off the engine before the oil level falls below the safety limit.

OPTIONS ON REQUEST